Testo 905-T2 Surface Thermometer – Spring-Loaded Type K Thermocouple Tip, −50…+350 °C (Short-Term +500 °C), Pipe and Installation Surface Measurement (0560 9056)
Testo 905-T2 Surface Thermometer – Spring-Loaded Type K Thermocouple Tip, −50…+350 °C (Short-Term +500 °C), Pipe and Installation Surface Measurement (0560 9056)
Testo 905-T2 Surface Thermometer – Spring-Loaded Type K Thermocouple Tip, −50…+350 °C (Short-Term +500 °C), Pipe and Installation Surface Measurement (0560 9056)
Testo 905-T2 Surface Thermometer – Spring-Loaded Type K Thermocouple Tip, −50…+350 °C (Short-Term +500 °C), Pipe and Installation Surface Measurement (0560 9056)
Testo 905-T2 Surface Thermometer – Spring-Loaded Type K Thermocouple Tip, −50…+350 °C (Short-Term +500 °C), Pipe and Installation Surface Measurement (0560 9056)
Testo 905-T2 Surface Thermometer – Spring-Loaded Type K Thermocouple Tip, −50…+350 °C (Short-Term +500 °C), Pipe and Installation Surface Measurement (0560 9056)
Testo 905-T2 Surface Thermometer – Spring-Loaded Type K Thermocouple Tip, −50…+350 °C (Short-Term +500 °C), Pipe and Installation Surface Measurement (0560 9056)
Testo 905-T2 Surface Thermometer – Spring-Loaded Type K Thermocouple Tip, −50…+350 °C (Short-Term +500 °C), Pipe and Installation Surface Measurement (0560 9056)
Testo 905-T2 Surface Thermometer – Spring-Loaded Type K Thermocouple Tip, −50…+350 °C (Short-Term +500 °C), Pipe and Installation Surface Measurement (0560 9056)
Testo 905-T2 Surface Thermometer – Spring-Loaded Type K Thermocouple Tip, −50…+350 °C (Short-Term +500 °C), Pipe and Installation Surface Measurement (0560 9056)
Testo 905-T2 Surface Thermometer – Spring-Loaded Type K Thermocouple Tip, −50…+350 °C (Short-Term +500 °C), Pipe and Installation Surface Measurement (0560 9056)
Testo 905-T2 Surface Thermometer – Spring-Loaded Type K Thermocouple Tip, −50…+350 °C (Short-Term +500 °C), Pipe and Installation Surface Measurement (0560 9056)
Testo 905-T2 Surface Thermometer – Spring-Loaded Type K Thermocouple Tip, −50…+350 °C (Short-Term +500 °C), Pipe and Installation Surface Measurement (0560 9056)
Testo 905-T2 Surface Thermometer – Spring-Loaded Type K Thermocouple Tip, −50…+350 °C (Short-Term +500 °C), Pipe and Installation Surface Measurement (0560 9056)
Testo 905-T2 Surface Thermometer – Spring-Loaded Type K Thermocouple Tip, −50…+350 °C (Short-Term +500 °C), Pipe and Installation Surface Measurement (0560 9056)
Testo 905-T2 Surface Thermometer – Spring-Loaded Type K Thermocouple Tip, −50…+350 °C (Short-Term +500 °C), Pipe and Installation Surface Measurement (0560 9056)
Testo 905-T2 Surface Thermometer – Spring-Loaded Type K Thermocouple Tip, −50…+350 °C (Short-Term +500 °C), Pipe and Installation Surface Measurement (0560 9056)

Testo 905-T2 Surface Thermometer – Spring-Loaded Type K Thermocouple Tip, −50…+350 °C (Short-Term +500 °C), Pipe and Installation Surface Measurement (0560 9056)

  • Stock: In Stock
  • Brand: Testo
  • Model: 0560 9056
$153.29 (VAT incl.)
Ex Tax: $127.74
Fast Dispatch
Shipped from Türkiye by international express courier (see delivery page)
Secure Shopping
Your card details cannot be seen by anyone, including our staff.
Shipping
Your discounted shipping rate is calculated in the cart.

Testo 905-T2 (product code 0560 9056) is a digital surface thermometer with a spring-loaded crossed-band type K thermocouple measuring tip, designed for temperature measurement on flat and rough surfaces. The spring-loaded thermocouple band adapts to the measured surface by itself; this prevents the probe from tilting and distorting the measurement result, and the tip picks up the surface temperature very quickly (t99 approx. 5 seconds). It measures in the range −50 … +350 °C, and briefly (1–2 minutes) up to +500 °C. It is used in heating, plumbing and refrigeration installations; since it has no problems with rough surfaces, it is especially suitable for measuring pipe surface temperature.

Fast Surface Temperature Measurement on Rough Surfaces and Pipes

The head carrying the display rotates, so readings can be read comfortably from different angles. It is operated with a single button: pressing the button once switches the instrument on, pressing it again toggles between the current value and HOLD (frozen value), and holding it for 3 seconds switches it off. If the button is held down at switch-on until the segment test is complete, the unit of measurement can be changed between °C/°F. If no button is pressed for approximately 10 minutes, the instrument switches off automatically. It comes with a multi-purpose clip and runs for approximately 1000 hours on 3 AAA batteries.

Technical Specifications (Official Testo Data)

  • Brand / Model: Testo 905-T2 surface thermometer · product code 0560 9056
  • Sensor: type K thermocouple, spring-loaded crossed-band measuring head
  • Measuring Range: −50 … +350 °C · short-term (1–2 minutes) +500 °C
  • Accuracy (±1 digit): ±(1 °C + 1% of reading) · relative to +25 °C nominal temperature
  • Resolution: 0.1 °C
  • Response Time: t99 approx. 5 seconds
  • Probe: shaft length 150 mm, shaft diameter 3 mm · measuring head diameter 12 mm, length 40 mm
  • Display: single-line LCD, rotating head · HOLD · °C / °F
  • Power Supply: 3 × AAA micro batteries · battery life approx. 1000 hours · auto-off approx. 10 min
  • Operating / Storage Temperature: 0 … +40 °C / −20 … +70 °C
  • Standard: CE 2014/30/EU
  • Housing / Dimensions / Weight: ABS plastic, black · 220 × 40 × 70 mm · 80 g

Scope of Delivery

  • Testo 905-T2 surface thermometer
  • Multi-purpose clip
  • Batteries

Technician Tips

  • Place the tip perpendicular to the surface: place the measuring head directly and perpendicularly on the surface; the spring-loaded thermocouple band adapts to the surface and gives an accurate and fast result.
  • Protect the crossed bands: the crossed metal bands on the probe tip are delicate; do not rub them against sharp edges or damage them.
  • Keep +500 °C brief: the continuous measuring range of the thermometer is up to +350 °C; measurements up to +500 °C must only be made for 1–2 minutes.
  • Wait when the environment changes: when the instrument is taken to an environment at a different temperature, an adjustment time of approximately 15 minutes is required. Do not leave the housing outside the 0 … +40 °C operating temperature, for example protect it from direct sunlight.
  • Do not measure on live parts: do not take measurements on or near electrically live parts. Remove the display protective film before first use; replace the 3 AAA batteries when the battery symbol appears on the display.

Technical document: Testo 905-T1 / 905-T2 datasheet (PDF, English)

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good

Loading...

Unlimited Blocks, Tabs or Accordions with any HTML content can be assigned to any individual product or to certain groups of products, like entire categories, brands, products with specific options, attributes, price range, etc. You can indicate any criteria via the advanced product assignment mechanism and only those products matching your criteria will display the modules.

Also, any module can be selectively activated per device (desktop/tablet/phone), customer login status and other criteria. Imagine the possibilities. 

Prices are shown in US dollars for reference, converted at the current exchange rate. Payment is charged in Turkish lira (TL); the amount on your card statement may differ slightly. Türkçe