Categories
Categories
My Cart
We use cookies in line with legal regulations to improve your shopping experience. For details, see our Cookie Policy.
Testo 184 T1 Transport Temperature Data Logger (USB Data Logger) – Single-Use, 90 Days, −35…+70 °C, 16,000 Readings, PDF Report, EN 12830 (0572 1841)
Testo 184 T1 Transport Temperature Data Logger (USB Data Logger) – Single-Use, 90 Days, −35…+70 °C, 16,000 Readings, PDF Report, EN 12830 (0572 1841)
Testo 184 T1 Transport Temperature Data Logger (USB Data Logger) – Single-Use, 90 Days, −35…+70 °C, 16,000 Readings, PDF Report, EN 12830 (0572 1841)
Testo 184 T1 Transport Temperature Data Logger (USB Data Logger) – Single-Use, 90 Days, −35…+70 °C, 16,000 Readings, PDF Report, EN 12830 (0572 1841)
Testo 184 T1 Transport Temperature Data Logger (USB Data Logger) – Single-Use, 90 Days, −35…+70 °C, 16,000 Readings, PDF Report, EN 12830 (0572 1841)
Testo 184 T1 Transport Temperature Data Logger (USB Data Logger) – Single-Use, 90 Days, −35…+70 °C, 16,000 Readings, PDF Report, EN 12830 (0572 1841)
Testo 184 T1 Transport Temperature Data Logger (USB Data Logger) – Single-Use, 90 Days, −35…+70 °C, 16,000 Readings, PDF Report, EN 12830 (0572 1841)

Testo 184 T1 Transport Temperature Data Logger (USB Data Logger) – Single-Use, 90 Days, −35…+70 °C, 16,000 Readings, PDF Report, EN 12830 (0572 1841)

  • Stock: In Stock
  • Brand: Testo
  • Model: 0572 1841
$82.94 (VAT incl.)
Ex Tax: $69.12
Fast Dispatch
Shipped from Türkiye by international express courier (see delivery page)
Secure Shopping
Your card details cannot be seen by anyone, including our staff.
Shipping
Your discounted shipping rate is calculated in the cart.

Testo 184 T1 (product code 0572 1841) is a USB-connected, single-use temperature data logger developed to monitor the road, rail and air transport of sensitive products requiring a cold chain, such as pharmaceuticals, food and electronics. With its internal NTC sensor it measures in the range of −35 … +70 °C with ±0.5 °C accuracy and stores up to 16,000 readings; with its non-replaceable internal battery it can be used for 90 days from the first program start. No software installation is required: settings are made with the PDF configuration file inside the logger, and when it is plugged into a computer a PDF report containing the measurement data is generated automatically. It is EN 12830 and HACCP International certified.

Cold Chain Transport Temperature Logging Without Installing Software

The logger is delivered in deep sleep mode to save battery; when the START or STOP button is pressed, it switches to standby mode. Logging starts by pressing the START button for about 3 seconds or automatically at the configured time; a start delay can be defined for button start. Logging ends by pressing the STOP button for 3 seconds or at the set time. To document the stages during transport when responsibility passes to another company, up to 10 time marks can be set by pressing the START button for 3 seconds.

The device has no display; at the destination it is enough to look at the LEDs: if the Alarm LED is green there has been no limit violation, if it is red an alarm has occurred; the Battery LED turns red when the remaining service life falls below 10 days; the Mode LED shows logging (green), end (red) and standby (green and red) status. The LEDs flash every 5 seconds to save battery.

When the logger is plugged into the USB port of a computer, the configuration PDF inside it is opened with Adobe Reader; settings such as the measuring interval (1 minute … 24 hours), start and stop criteria, and a single alarm or a cumulative alarm triggered when the permitted total time is exceeded are made and saved to the logger. The same setting can be used as an XML file as a template for other loggers, and a company logo can be added to the report. At the end of transport, when the logger is plugged into a Windows computer, the generated PDF report can be opened and printed or sent by e-mail; the configuration file, calibration protocol, user manual and PDF report are stored inside the logger. Thanks to the NFC interface, data can be transferred wirelessly to the Testo mobile printer (0572 0576) for printing in the field.

Technical Specifications (Official Testo Information)

  • Brand / Model: Testo 184 T1 USB transport temperature data logger · product code 0572 1841
  • Sensor / Channel: internal NTC temperature sensor · 1 internal channel
  • Measuring Range: −35 … +70 °C (°C / °F)
  • Accuracy / Resolution: ±0.5 °C · 0.1 °C
  • Response Time: t90 = 30 minutes
  • Logging Interval: 1 minute … 24 hours
  • Memory: 16,000 readings
  • Service Life: 90 days from the first program start (5 min measuring interval, −35 °C) · single-use logger
  • Power Supply: internal lithium battery, non-replaceable
  • Indication: Alarm, Battery and Mode LEDs (no display)
  • Interface: USB, NFC · Adobe Reader for configuration and report · compatible with ComSoft Professional and ComSoft CFR software (optional)
  • Operating / Storage Temperature: −35 … +70 °C / −35 … +70 °C · can be stored for a maximum of 1 year after delivery
  • Protection Class: IP65
  • Standard / Certification: EN 12830 · HACCP International · GxP · 21 CFR Part 11 with ComSoft CFR software · CE, RTCA/DO-160G · 2014/30/EU, 2011/65/EU, DIN EN 50581, DIN EN 61326-1
  • Housing / Dimensions / Weight: ABS plastic, white · 35 × 9 × 75 mm · approx. 25 g

Scope of Delivery

  • Testo 184 T1 temperature data logger (internal battery fitted)
  • ISO test protocol (also stored as PDF inside the logger)
  • Double-sided adhesive mounting pad for fixing the logger

Technician Tips

  • Plan the stock period: the logger can be stored for a maximum of 1 year after delivery; the 90-day service life starts with the first program start. Plan loggers in stock so that they are used within these periods.
  • Prepare several loggers with the same settings: leave the configuration PDF open and plug in the loggers one after another to save the same settings. Do not copy-paste the XML file onto the logger; local time and time zone settings are not transferred this way.
  • Document handover points with time marks: when responsibility passes to another company, set a time mark by pressing the START button for 3 seconds; Min, Max and alarm values are reset with each mark.
  • Use software for long recordings: the graph in the PDF report is drawn with a maximum of 324 readings; for longer recordings, Testo ComSoft software is recommended to see all values.
  • Activate NFC in advance: the NFC function is disabled in the factory settings; if printing with the mobile printer is required, enable it in the configuration file. NFC data cannot be read with Android or Apple phones.

Technical document: Testo 184 data logger user manual (PDF, Turkish) · Testo 184 T1 / T2 / T3 datasheet (PDF, English)

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good

Loading...

Unlimited Blocks, Tabs or Accordions with any HTML content can be assigned to any individual product or to certain groups of products, like entire categories, brands, products with specific options, attributes, price range, etc. You can indicate any criteria via the advanced product assignment mechanism and only those products matching your criteria will display the modules.

Also, any module can be selectively activated per device (desktop/tablet/phone), customer login status and other criteria. Imagine the possibilities. 

Prices are shown in US dollars for reference, converted at the current exchange rate. Payment is charged in Turkish lira (TL); the amount on your card statement may differ slightly. Türkçe