LG MBT038WMA Scroll Compressor – 5 HP, R404A, 9,582 W / 32,694 BTU/h, 380-420 V 3-Phase
LG MBT038WMA Scroll Compressor – 5 HP, R404A, 9,582 W / 32,694 BTU/h, 380-420 V 3-Phase
LG MBT038WMA Scroll Compressor – 5 HP, R404A, 9,582 W / 32,694 BTU/h, 380-420 V 3-Phase
LG MBT038WMA Scroll Compressor – 5 HP, R404A, 9,582 W / 32,694 BTU/h, 380-420 V 3-Phase
LG MBT038WMA Scroll Compressor – 5 HP, R404A, 9,582 W / 32,694 BTU/h, 380-420 V 3-Phase

LG MBT038WMA Scroll Compressor – 5 HP, R404A, 9,582 W / 32,694 BTU/h, 380-420 V 3-Phase

  • Stock: In Stock
  • Brand: Lg
  • Model: MBT038WMA
$406.01 (VAT incl.)
Ex Tax: $338.34
Fast Dispatch
Shipped from Türkiye by international express courier (see delivery page)
Secure Shopping
Your card details cannot be seen by anyone, including our staff.
Shipping
Your discounted shipping rate is calculated in the cart.

LG MBT038WMA is a 5 HP scroll hermetic compressor manufactured for commercial refrigeration. It operates with R404A and has a 380-420 V three-phase supply. At condensing 40 °C / evaporating −10 °C it delivers a cooling capacity of 9,582 W (32,694 BTU/h).

Scroll Technology: Fewer Parts, Quieter Operation, High Efficiency

A scroll compressor has no valves, piston rings or crank-connecting rod assembly as in the reciprocating type; compression takes place continuously and in one direction between two scrolls. In the field this means three things: fewer moving parts (smaller failure surface), lower vibration and noise, and a design that is more tolerant of liquid slugging.

In addition, the compression chamber of a scroll compressor empties completely on each revolution — there is no clearance volume. This means higher volumetric efficiency than an equivalent reciprocating compressor, especially at low evaporating temperatures.

Nominal Cooling Capacity (W)

Return gas temperature 18.3 °C · subcooling 0 °C · ambient 35 °C · 50 Hz · values have a ±5% tolerance.

Condensing \ Evaporating−20 °C−15 °C−10 °C−5 °C0 °C+5 °C
40 °C6,5937,9709,58211,45713,53815,911
45 °C6,0667,3558,82010,54912,48314,710
55 °C4,9235,9487,1798,61510,22712,102

How to read the table? The row on the left is the condensing temperature at which your condenser operates, and the column at the top is the evaporating temperature of your evaporator. In hot climates or with a dirty condenser, the condensing temperature rises: the same compressor operating at 55 °C instead of 40 °C delivers 7,179 W instead of 9,582 W at −10 °C. Make your selection based on your actual operating conditions.

Technical Specifications (Official LG Performance Document)

  • Model: LG MBT038WMA · scroll hermetic compressor
  • Power: 5 HP · refrigerant: R404A
  • Power supply: 380-420 V / 50 Hz · 460 V / 60 Hz · three-phase
  • Running current: 7.9 A
  • Starting current (LRA): 65 A — use this value as the basis for fuse and contactor selection
  • Max. operating current: 13 A — the overload relay is set according to this value
  • Suction tube: 7/8" · discharge tube: 1/2"
  • Capacity (ASHRAE 7.2 °C / 54.4 °C): 13,218 W
  • Application: commercial refrigeration · cold rooms · blast freezer rooms · supermarket display case racks
  • 🔧 Phase sequence is critical. A scroll compressor rotates in one direction only. If the phase sequence is reversed in a three-phase connection, the compressor runs backwards: pressure does not build up, noise rises abnormally and it is damaged in a short time. At first start-up, verify that the discharge pressure rises; if it does not, swap two phases.
  • 🔧 Electrical installation: the starting current rises to 65 A. Select the contactor, fuse and cable cross-section according to this value; set the overload relay to the 13 A maximum operating current. Use a phase protection relay — phase loss, phase sequence error and undervoltage are the three most common causes of scroll compressor failure.
  • 🔧 Crankcase heater: Prevents refrigerant migration into the oil during standstill. After long standstills, it is recommended that the heater be energized for at least 8-12 hours before starting the compressor.
  • 🔧 Use a suction line filter and a filter drier in the liquid line. Scroll wraps have tight tolerances; solid particles entering the system cause direct wear.
  • ⚠️ Oil and moisture: POE oil is used with R404A, and POE is hygroscopic; do not leave the lines open and pull a full vacuum.
  • Application limit: This model is for R404A. Use with other refrigerants requires manufacturer approval.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good

Loading...

Unlimited Blocks, Tabs or Accordions with any HTML content can be assigned to any individual product or to certain groups of products, like entire categories, brands, products with specific options, attributes, price range, etc. You can indicate any criteria via the advanced product assignment mechanism and only those products matching your criteria will display the modules.

Also, any module can be selectively activated per device (desktop/tablet/phone), customer login status and other criteria. Imagine the possibilities. 

Prices are shown in US dollars for reference, converted at the current exchange rate. Payment is charged in Turkish lira (TL); the amount on your card statement may differ slightly. Türkçe