KELI EPM 220-240V 18W Solenoid Water Pump (Steam Cleaning Machine)
- Stock: In Stock
- Brand: KELI
- Model: B2184EPM105A
An electromagnetic vibration water pump that service companies can use confidently when repairing steam cleaning machines, spot cleaning (stain removal) guns, steam generator irons and steam mops. The KELI EPM series is designed for compact appliances requiring a constant flow of water and steam with low energy consumption (18W); thanks to its continuous duty (ED 100%) capacity, it resists coil heating in constantly triggered steam systems.
Continuous Duty (ED 100%) for Steam Cleaning and Spot Cleaning Machines
- Brand and Model: KELI / EPM (Series: A-12)
- Product Code: B2184EPM105A
- Operating Voltage and Power: 220-240V 50/60Hz / 18W (fully compatible with standard mains voltage, low current draw).
- Duty Cycle: ED 100%. Designed to run continuously energized without needing a rest period.
- Insulation Class: CL.H (high-temperature-resistant winding); the body bears CE and TÜV SÜD certification marks.
- Fluid Temperature Limit: The temperature of the transferred water must not exceed Tf 35°C.
- Body and Connection: Zinc-plated steel body, dual faston (blade) terminal input, stepped plastic inlet and outlet nipples (hose barbs).
KELI EPM (Series: A-12) Technical Specifications and Field Installation Warnings
- The operating band specified by the manufacturer for the KELI EPM series is 2.5-8 bar pressure and 45-400 ml/min flow; the 18W model sits in the lower-middle segment of this band and is positioned for constant, low-flow steam supply. The ideal fluid for the pump is pure or softened water.
- Do not run dry. The EPM series does not have a dry running feature; a pump run with an empty water tank or a clogged scale filter will suffer piston and coil damage. Always clean the water passages and filter before installation.
- When removing the faulty pump, transfer the rubber vibration mounts on the body to the new pump; this keeps the appliance running quietly and reduces vibration fatigue on the chassis.
- The faston terminals are of standard design. Connect the wires strictly according to the appliance's original diagram and make sure the connectors are fully seated. The pump body heats up during operation; do not let the wiring harness touch the body.
- It should be used at ambient temperatures of 0-60°C. To ease suction, the pump should be mounted as far below the water tank level as possible, with the inlet nipple facing down.
Loading...
Unlimited Blocks, Tabs or Accordions with any HTML content can be assigned to any individual product or to certain groups of products, like entire categories, brands, products with specific options, attributes, price range, etc. You can indicate any criteria via the advanced product assignment mechanism and only those products matching your criteria will display the modules.