KELI EPLA-L 220-240V 35W Solenoid Water Pump (ULKA EP8 Equivalent)
- Stock: In Stock
- Brand: KELI
- Model: B2184EPL093A
This is an electromagnetic vibratory water pump designed for systems requiring low pressure and continuous flow, which service technicians can rely on when repairing steam generator irons, steam cleaners, medical devices and coffee machines. A direct equivalent of the ULKA EP8 model, considered the industry standard, it offers long-lasting, compatible and reliable repairs in the field with its continuous duty (ED 100%) capability.
ULKA EP8 Equivalent Water Pump Suitable for Continuous Duty (ED 100%)
- Brand and Model: KELI / EPLA-L (Series: 04)
- Operating Voltage and Power: 220-240V 50/60Hz / 35W (Fully compatible with standard mains voltage, stable coil draw).
- Pressure Capacity: Maximum delivery pressure of 0.3 MPa (approx. 3 Bar). Ideal for appliances that need a constant-flow liquid or steam feed rather than high pressure.
- Duty Cycle: ED 100%. Unlike other pumps, it is specially designed to run continuously under constant power (without needing a rest period).
- Insulation Class: CL.H (Winding resistant to high heat and CE/TUV-certified safety design).
- Liquid Temperature Limit: The maximum temperature of the transferred water must be Tf 35°C.
KELI EPLA-L (Series: 04) Technical Features and Installation Warnings in the Field
- This pump has exactly the same mechanical connection dimensions and electrical pin layout as the ULKA EP8. When replacing the faulty pump, do not forget to transfer the rubber vibration dampers (mounts) from the old pump body to the new KELI pump; this ensures quiet operation of the iron or coffee machine.
- Because the pump has an ED 100% rating, it does not burn out its coil or lose pressure when the trigger is held for a long time on steam generator irons. However, if the appliance's scale filter is clogged, a pump exposed to dry running will be damaged over time. Always clean the water passages before installation.
- The connection terminals (faston inputs) at the back of the pump are standard. When connecting the cables, follow the appliance's original wiring and make sure the connectors are fully seated (with no looseness).
Loading...
Unlimited Blocks, Tabs or Accordions with any HTML content can be assigned to any individual product or to certain groups of products, like entire categories, brands, products with specific options, attributes, price range, etc. You can indicate any criteria via the advanced product assignment mechanism and only those products matching your criteria will display the modules.