Cubigel NUT60CAb Hermetic Compressor – 1/4 HP, R290, LBP 304 W
- Stock: In Stock
- Brand: Cubigel
- Model: NUT60CAb
Cubigel NUT60CAb (NUT60CA) is a 1/4 HP hermetic reciprocating compressor built for commercial refrigeration appliances operating at sub-zero temperatures, such as small freezers, ice cream cabinets and chest freezers. It runs on R290 (propane); with a 6.00 cm³ displacement it delivers 304 W (1,037 BTU/h) at ASHRAE LBP conditions of cooling capacity.
R290 Propane LBP Compressor: For Small Freezers and Ice Cream Cabinets
With its compact U series body, fan-cooled design and RSCR (PTC relay, run capacitor) motor, the NUT60CAb operates in the −40 … −10 °C evaporating range and is designed for capillary tube systems. Thanks to its run capacitor motor, it offers low energy consumption with COP 1.82 at ASHRAE conditions. Propane has a GWP of 3, making it a suitable option for low-charge systems unaffected by F-Gas restrictions.
Key Technical Specifications and Equipment
- Brand / Model: Cubigel NUT60CAb · U series
- Refrigerant: R290 (propane) · EN 60335-1 and EN 60335-2-34 explosion safety approved for R290 and R600a
- Application: LBP (low back pressure) · evaporating −40 … −10 °C
- Displacement: 6.00 cm³ · bore 21.99 mm · stroke 16.00 mm
- Motor: RSCR · locked rotor current (LRA) 7.1 A · max. continuous current 1.6 A
- Winding resistance (25 °C): main 13.25 Ω · auxiliary 15.70 Ω
- Power supply: 220-240 V / 50 Hz single-phase · operating range 187-255 V
- Cooling: fan-cooled · expansion: capillary tube
- Oil: ISO VG 10 ester, 200 cm³
- Tube inner diameters: service Ø6.2 · suction (direct) Ø6.2 · discharge Ø4.9 mm
- Dimensions: height 173.5 mm · base 204 × 158 mm (228 mm with terminal box)
- Mounting holes: 6 × Ø16 (170 × 70 mm)
- Weight: 9.31 kg · max. ambient temperature 43 °C
Performance (ASHRAE, Condensing +55 °C)
| Evaporating | Capacity | Input power | COP |
|---|---|---|---|
| −40 °C | 124 W | 106 W | 1.17 |
| −35 °C | 165 W | 124 W | 1.33 |
| −30 °C | 216 W | 142 W | 1.52 |
| −25 °C | 279 W | 161 W | 1.74 |
| −23.3 °C (LBP) | 304 W (1,037 BTU/h) | 167 W | 1.82 |
| −20 °C | 354 W | 179 W | 1.97 |
| −15 °C | 438 W | 198 W | 2.22 |
| −10 °C | 535 W | 217 W | 2.47 |
ASHRAE: liquid and ambient 32 °C, suction 32 °C. At CECOMAF conditions (−25 °C, liquid 55 °C): 226 W, 161 W input power, COP 1.41. Capacity decreases as the evaporating temperature drops; choose according to your cabinet's target temperature.
Electrical Equipment (Manufacturer References)
- Run capacitor: 5 µF 400 V
- Relay: PTC K100 (200-240 V · 14 Ω)
- Thermal protector: T0508, AE18FU or B65-135 (6.3-6.5 A · open / close 120-135 / 61-62 °C)
- 🔥 R290 is a flammable refrigerant (class A3). Brazing, leak testing and gas charging must follow the rules for flammable refrigerants: a ventilated area, no ignition sources and compliance with charge limits are mandatory. This compressor is for R290 systems only.
- 🔧 When replacing: In the RSCR connection the PTC relay and 5 µF run capacitor are used together; compare the old compressor's refrigerant, LBP class and mounting hole spacing against the dimensional drawing. Intended for capillary tube systems.
- Application limit: This model is LBP — intended for freezer and low-temperature applications. It is not used in positive-temperature coolers (HBP).
Loading...
Unlimited Blocks, Tabs or Accordions with any HTML content can be assigned to any individual product or to certain groups of products, like entire categories, brands, products with specific options, attributes, price range, etc. You can indicate any criteria via the advanced product assignment mechanism and only those products matching your criteria will display the modules.