CIMM Ferroli Boiler Expansion Vessel 8 L 3/4" – CP335, Compatible with 39809020, Round
- Stock: In Stock
- Brand: CIMM
- Model: CMM35
The CIMM CP335 replaces the 8-litre, 3/4" connection expansion vessel with part number 39809020 in Ferroli boilers (expansion tank). It absorbs the extra volume as the heating water warms up, keeps the system pressure balanced and prevents the safety valve from opening unnecessarily. It has a round flat body (Ø325 × 132 mm); the connection comes out radially from the rim (0° position). It has an SBR membrane and a factory pre-charge of 1.5 bar. It is made in Italy by CIMM.
Which Boilers Is It Used In?
- In Ferroli boilers whose parts list shows expansion vessel 39809020.
- Before ordering, compare the diameter (Ø325 mm), volume (8 L), connection (3/4" male thread) and connection position of the old vessel.
Fault Symptoms
- As the boiler heats up, the pressure quickly rises to 3 bar and the safety valve discharges water.
- The pressure drops when the boiler is cold and rises when it heats up; the system needs topping up often.
- The pre-charge measured at the air valve is zero or very low; if water comes out when the valve is pressed, the membrane is torn.
When Replacing
- Switch off the boiler power, close the system valves and release the boiler pressure.
- Undo the connection fitting; renew the gasket and do not reuse the old one.
- Before fitting, check the vessel pre-charge with a gauge; if it differs from the value in the boiler manual, adjust it at the air valve.
- Refill the system and run the boiler; check that the pressure does not approach 3 bar while heating up.
Technical Specifications
| Brand / Model | CIMM CP335 |
| Ferroli part no. | 39809020 |
| Volume | 8 L |
| Connection | 3/4" male thread, radial (0°) |
| Body | Round, flat · Ø325 × 132 mm |
| Membrane | SBR |
| Pre-charge | 1.5 bar |
| Max. working pressure | 3.0 bar |
| Test pressure | 4.3 bar |
| Operating temperature | −10 … +90 °C |
| Standard / approval | EN 13831 · PED 2014/68/EU · DIN CERTCO 5C019 |
| Made in | Italy |
Frequently Asked Questions
What should the pre-charge be?
The vessel comes with a 1.5 bar pre-charge. If the boiler manual specifies a different value, adjust it at the air valve before fitting; measure with the system pressure released.
What does "0 degrees" mean?
It shows the position of the connection on the body; on this vessel the 3/4" connection comes out radially from the rim of the round body. If the old vessel has its connection in a different position, the pipe cannot be connected without strain; compare the connection position.
Loading...
Unlimited Blocks, Tabs or Accordions with any HTML content can be assigned to any individual product or to certain groups of products, like entire categories, brands, products with specific options, attributes, price range, etc. You can indicate any criteria via the advanced product assignment mechanism and only those products matching your criteria will display the modules.
Also, any module can be selectively activated per device (desktop/tablet/phone), customer login status and other criteria. Imagine the possibilities.