Bosch Buderus GB112 / GB162 Boiler Ionisation Electrode – Compatible with 7100238 (G-Force)
- Stock: In Stock
- Brand: G-Force
- Model: 77890012028
This boiler ionisation electrode detects the flame on the burner of Buderus Logamax plus GB112 condensing boilers and replaces the electrode with original part number 7100238. When the burner flame is established, the electrode passes the ionisation current to the boiler PCB; if the PCB does not receive this signal, it closes the gas valve and locks out. It has a single straight rod, a ceramic body and a sheet metal flange; the lead ends in a socket with a male spade terminal. It is a G-Force replacement flame sensing electrode.
Which Boilers Is It Used In?
- In Buderus boilers whose parts list includes ionisation electrode 7100238.
- Appliances for which the Bosch spare parts catalogue lists this part: Logamax plus GB112-29 and GB112-43; Buderus-Sieger BK11, BK13 and BK15 series wall-hung boilers.
- The manufacturer's part record gives its use as GB112–GB162 and GB202.
- Before ordering, compare the rod shape and flange of the old electrode.
Fault Symptoms
- The boiler lights and the flame is visible, but it goes out after a few seconds and locks out; this usually means the flame is not being detected.
- The boiler makes repeated ignition attempts and locks out.
- The electrode tip is dirty or worn, or the ceramic body is cracked.
When Replacing
- Switch off the electricity and gas to the boiler; work only after the burner has cooled down.
- The electrode gasket is not included. If the old gasket is hardened or torn, use a new one.
- Keep the distance between the electrode tip and the burner the same as on the old part; do not bend the rod.
- Reconnect the lead to its original position and light the boiler several times to check that the flame stays on.
Technical Specifications
| Brand | G-Force |
| Buderus part no. | 7100238 |
| Type | Ionisation (flame sensing) electrode, single rod |
| Body | Ceramic insulator, sheet metal flange |
| Connection | With lead, socket with male spade terminal |
| Compatible with | Buderus Logamax plus GB112; Buderus-Sieger BK11, BK13, BK15 |
| Gasket | Not included |
Frequently Asked Questions
Is it the same part as the ignition electrode?
No. On the GB112 the spark is produced by the ignition electrode; this part only detects the flame. The ignition electrode is listed separately on our site.
Is a gasket included?
No. The product is the electrode with its lead only. Order a gasket separately if needed.
Is it a Buderus branded part?
No. It is a G-Force replacement electrode used in place of part number 7100238.
Loading...
Unlimited Blocks, Tabs or Accordions with any HTML content can be assigned to any individual product or to certain groups of products, like entire categories, brands, products with specific options, attributes, price range, etc. You can indicate any criteria via the advanced product assignment mechanism and only those products matching your criteria will display the modules.