Artiko RVG-10C Single-Valve Digital Manifold Full Set – 88 Refrigerants, With Hoses (With Case)
- Stock: In Stock
- Brand: Artiko
- Model: 01 19 69
Artiko RVG-10C is a pocket-sized digital manifold / digital pressure gauge with a single body and a single valve. It measures pressure and temperature simultaneously; when you select the refrigerant from its built-in library of 88 refrigerants with NIST data, it calculates the superheat and subcooling values itself. This full set version comes in a carrying case with charging hoses, a clamp temperature probe and valve adapters — you can take it out of the box and start work right away.
Single-Valve Digital Manifold: Pocket-Sized Superheat/Subcooling Measurement
- Difference from an analog gauge: You don't turn a slide rule and read a P-T table; you select the refrigerant and the device calculates. ±0.5% FS accuracy and 0.5 psi resolution are much clearer than reading a needle.
- One valve, two jobs: Connects to the low or high side with a single line; charge/recovery control via the service valve is done with one hand. For small split servicing there is no need to carry a large two-valve manifold.
- Clamp probe included: Attaches to the pipe; pressure + pipe temperature are read together and superheat/subcooling is monitored live.
- Vacuum monitoring: Shows the negative pressure side (down to -14.5 psi); you monitor the evacuation of the system on the same device.
- 6 pressure units: kPa · MPa · psi · inHg · bar · kg/cm² | °C/°F selectable.
Technical Specifications, Set Contents and Usage Notes
- Product Code: 01 19 69 | Model: Artiko RVG-10C (full set)
- Pressure Measurement: -14.5 ~ 800 psi · resolution 0.5 psi · accuracy ±0.5% FS
- Temperature Measurement: -50 ~ +150°C · resolution 0.1°C · accuracy ±0.5°C
- Refrigerant Library: 88 refrigerants (US NIST data) — including R32, R410A, R134a, R22, R404A, R407C
- Operating Temperature: -10 ~ +50°C · backlit display (LIGHT button) · ZERO function
- Set Contents: RVG-10 body + 2 charging hoses + clamp-type temperature probe + 2 valve adapters + carrying case + manual
- Warning: Cannot be used with ammonia (NH₃) refrigerants; compatible with non-corrosive refrigerants, water and glycol.
- 🔧 Zero before measuring — zeroing with the manifold unpressurized compensates for altitude/atmospheric pressure differences.
- Attach the clamp probe to bare copper; measuring over insulation skews the superheat calculation by 2-3°C.
- Do not leave the device on the line during pressure tests above 800 psi — the display shows "OL" and the sensor is strained.
Loading...
Unlimited Blocks, Tabs or Accordions with any HTML content can be assigned to any individual product or to certain groups of products, like entire categories, brands, products with specific options, attributes, price range, etc. You can indicate any criteria via the advanced product assignment mechanism and only those products matching your criteria will display the modules.
Also, any module can be selectively activated per device (desktop/tablet/phone), customer login status and other criteria. Imagine the possibilities.