Artiko DMG-360 Digital Manifold Full Set – 19 Refrigerants, Dual Sensor, with Case
- Stock: In Stock
- Brand: Artiko
- Model: 01 19 67
Artiko DMG-360 is a digital manifold set with dual pressure sensors. It shows low and high pressure simultaneously on two separate LCD displays; when you select the refrigerant you are working with from the 19 refrigerants in its memory, it calculates the saturation temperature accordingly. It comes as a complete set with charging hoses, quick coupler adapters and a carrying case — take it out of the box and start work.
19-Refrigerant Memory and Dual Pressure Sensors
- Where analog gauges fall short: No more turning refrigerant slide charts or reading P-T tables; you select the refrigerant and the device does the reading. 0.01 bar resolution and ±0.2 bar accuracy are much clearer than reading a needle.
- 19 refrigerant support: R134A, R1234yf, R22, R290, R32, R404A, R407C, R410A, R452b, R454b, R502, R507, R600, R600A, R12, R125, R141b, R401A, R401b — including new-generation low-GWP refrigerants (R32, R1234yf, R454b, R452b).
- Vacuum from the same device: Reads vacuum down to -29 inHg; you monitor system evacuation without changing the manifold.
- 5 pressure units: bar · psi · kPa · MPa · kgf/cm² | temperature °C/°F.
- Independent in the field: 60 hours of operation on 2 × 9V batteries; backlit display, 30-minute auto power-off.
Technical Specifications, Set Contents and Usage Notes
- Product Code: 01 19 67 | Model: Artiko DMG-360
- Sensor: 2 built-in pressure sensors | Refresh Rate: 1 second
- Pressure Range: 0-60 bar (0-870 psi · 0-6,000 kPa · 0-6 MPa · 0-61 kgf/cm²)
- Vacuum Range: -29 ~ 0 inHg | Max. Overload: 75 bar
- Resolution: 0.01 bar · 0.1 psi · 1 kPa · 0.001 MPa · 1 inHg
- Accuracy (22 °C): ±0.2 bar (±2 psi · ±20 kPa) | ±1 inHg in vacuum
- Connection: 1/4" SAE | Operating Humidity: 10-90% RH
- Operating Temperature: -10 ~ +50 °C | Storage: -20 ~ +60 °C
- Power: 2 × 9V dry batteries — 60 hours | Display: Backlit LCD (1 min), 30 min auto power-off
- Set Contents: DMG-360 manifold + charging hoses + quick coupler adapters + carrying case + user manual
- 🔧 Not for use with ammonia (R-717). The manufacturer explicitly excludes ammonia and ammonia-containing refrigerants; the sensor will be damaged.
- Do not leave it on a line above 75 bar: The measuring limit is 60 bar and the overload limit is 75 bar — disconnect the device from the line during pressure testing.
- Select the refrigerant correctly: Saturation temperature and superheat/subcooling calculations are based on the selected refrigerant; selecting the wrong refrigerant does not spoil the measurement but the interpretation.
- Remove the batteries if it will not be used for a long time — a leaking battery damages the electronic board. The 30-minute auto power-off preserves battery life.
Loading...
Unlimited Blocks, Tabs or Accordions with any HTML content can be assigned to any individual product or to certain groups of products, like entire categories, brands, products with specific options, attributes, price range, etc. You can indicate any criteria via the advanced product assignment mechanism and only those products matching your criteria will display the modules.